ΠΕΝΤΑΧΣ Διάταξη κάμψης EG-2990I για ενδοσκόπηση
| Brand: | Πεντάξ | Model: | EG-2990i |
| Series: | Τμήμα κάμψης | Condition: | Ολοκαίνουργιο |
| Material: | Ιατρικό ανοξείδωτο ατσάλι υψηλής ποιότητας | Angulation Range(Up / Down): | 210° / 120° |
| Angulation Range(Right / Left): | 120°/120° | MOQ: | 1 Τεμάχιο |
| Package: | Χαρτοκιβώτιο / Τυπική συσκευασία εξαγωγής | Transportation: | DHL, FedEx, UPS κ.λπ. |
| In Stock: | Ναί | Price: | Accept Negotiation |
| High Light: | ΠΕΝΤΑΧΣ Κουμπώμενο τμήμα,Ενδοσκοπική κάμψη,EG-2990I Τμήμα κάμψης |
||
Bending Section Assembly for Pentax EG-2990i Video Gastroscope
► Brief Description
The bending section assembly is a vital structural and mechanical module located at the distal end of the Pentax EG-2990i video gastroscope. It provides the precise articulation required to navigate the complex anatomical pathways of the upper gastrointestinal tract (esophagus, stomach, and duodenum) during diagnostic and therapeutic procedures.
► Features
- Precise Maneuverability: Enables smooth, multi-directional steering to locate hard-to-view areas within the gastric folds and duodenal bulb.
- Durability and Flexibility Balance: The segmented spine design balances maximum flexibility with structural resilience against repeated mechanical stress.
- Optimized Channel Integration: Houses and protects the instrument working channel, air/water nozzles, and light guide fiber bundles without compromising bending performance.
► Specification
| Brand | PENTAX |
| Model | EG-2990I |
| Series | Bending Section |
| Condition | Brand-new |
| Material | High-grade Medical Stainless Steel |
| Angulation Range(Up / Down) | 210° / 120° |
| Angulation Range(Right / Left) | 120°/ 120° |
| MOQ | 1 Piece |
| Package | Carton / Standard Export Packing |
| Transportation | DHL, FedEx, UPS, etc. |
| In Stock | Yes |
| Price | Accept Negotiation |
►FAQ
What obvious signs indicate the bending section assembly needs immediate replacement?
A: You must replace the assembly right away when these issues occur:
- Bending rubber cracks, peels or has obvious blisters on the surface
- Bending resistance increases significantly, and the angle cannot reach the standard range
- Water leakage or air leakage occurs during the leak test, triggering the host alarm
- The image is blocked or the light guide is broken due to internal fiber damage
What are the main causes of premature damage to the EG-2990I bending section?
A: The top factors leading to early failure include:
- Improper operation during examination, forcing the gastroscope to bend beyond the designed angle
- Long-term immersion in disinfectant with excessive concentration, leading to rubber material aging
- Scratches from sharp biopsy accessories during insertion and withdrawal operations
What are the prohibited operations during daily use and maintenance?
A: Do not use sharp tools to scrape the bending rubber surface during cleaning
- Do not bend the section forcibly beyond the maximum designed angle during operation
- Do not soak the assembly in disinfectant for a time longer than the specified limit
- Do not perform leak test with damaged bending rubber, to avoid fluid intrusion that burns out internal circuits
► More service