Found 90 products for "

rigid endoscope repair

"
Ποιότητα Ορετερορονοσκόπιο γερμανικής ποιότητας 4.5/6.5 6/7.5 6/8.5 8/9.8 8.5/11/5 Fr Για νοσοκομείο Εργοστάσιο

Ορετερορονοσκόπιο γερμανικής ποιότητας 4.5/6.5 6/7.5 6/8.5 8/9.8 8.5/11/5 Fr Για νοσοκομείο

German-quality Ureterorenoscope 4.5/6.5 6/7.5 6/8.5 8/9.8 8.5/11/5 Fr For Hospital ► Brief Description The function of a ureterorenoscope (URS) is primarily to allow a urologist to visualize, diagnose, and treat conditions in the upper urinary tract, which includes the ureter (the tube carrying urine from the kidney to the bladder) and the renal pelvis/calyces (the collecting system inside the kidney). ► Features Adopts a sapphire lens that is heat-resistant, wear-resistant,

Ποιότητα Ενδοσκόπιο Olympus TJF-160VR για επισκευή Εργοστάσιο

Ενδοσκόπιο Olympus TJF-160VR για επισκευή

Olympus TJF-160VR endoscope for repair ► Brief Description Fault: 1.No image, CCD broken. 2. Light bundle broken completely. 3. Insert tube aging and wrinkle. 4. Biopsy tube broken. 5. Wires and helix tube broken. 6. clamp wires broken. 7. Operation part broken, no angle. 8. Grip broken. 9. The scope be separated by someone before, some parts missing. Solution: Replace digital parts,CCD,light bundle,insert tube, biopsy tube,air&water tube, bending section, wires,helix tube,

Ποιότητα Ενδοσκόπιο Olympus CHF-P20Q για επισκευή Εργοστάσιο

Ενδοσκόπιο Olympus CHF-P20Q για επισκευή

Olympus CHF-P20Q endoscope for repair ► Brief Description Fault: 1.Insert tube cracked; 2.Rubber leakage; 3.Image with black point and cracked; 4.Angulation tight; 5.Biopsy tube aging Solution: Replace image bundle; insert tube; biopsy tube; bending mesh and wires; coil pipe; rubber ►Problem & Solutoin Brand Olympus Model CHF-P20Q Fault 1.Insert tube cracked; 2.Rubber leakage; 3.Image with black point and cracked; 4.Angulation tight; 5.Biopsy tube aging Solution Replace image

Ποιότητα Εργαλείο επισκευής για Olympus Otv-S7proh-Hd-12 Otv-S7proh-Hd-12e Q Otv-S7proh-Hd καλώδιο Εργοστάσιο

Εργαλείο επισκευής για Olympus Otv-S7proh-Hd-12 Otv-S7proh-Hd-12e Q Otv-S7proh-Hd καλώδιο

REPAIR TOOLS FOR OLYMPUS OTV-S7ProH-HD-12 OTV-S7PROH-HD-12E/Q OTV-S7PROH-HD CABLE Brand: OLYMPUS Model: OTV-S7ProH-HD-12 OTV-S7PROH-HD-12E/Q OTV-S7PROH-HD Condition: Brand new A repair tool that can be used to repair OLYMPUS OTV-S7ProH-HD-12 OTV-S7PROH-HD-12E/Q OTV-S7PROH-HD cable. It can be securely fixed and easy to repair cable. We provide trading and service of Ultrasound unit/Transducer, Dynamic system device/parts, Rigid endoscope parts and Flexible endoscope parts, we

Ποιότητα Το κολονοσκόπιο Olympus CF-H190L για επισκευή Εργοστάσιο

Το κολονοσκόπιο Olympus CF-H190L για επισκευή

Olympus CF-H190L Colonoscope for repair ► Brief Description Fault: 1. Image ok; 2. Light bundle still ok; 3. The front end of the insert tube is broken, and the serpentine; the position of stress boot is leaking; 4. Biopsy tube wear; 5. Left Angle failure, bending section, wire and helix tube wear; 6. Soft and hard adjustment wire wear, relatively tight; 7. Rubber leakage. Solution: Replace the insertion tube, biopsy tube, bending section, wire, helix tube, soft and hard

Ποιότητα Το γαστροσκόπιο Olympus GIF-Q180 για επισκευή Εργοστάσιο

Το γαστροσκόπιο Olympus GIF-Q180 για επισκευή

Olympus GIF-Q180 gastroscope for repair ► Brief Description Fault: 1.image definition not enough, CCD aging. 2.30% light bundle broken. 3. Insert tube aging and wrinkle. 4.Biopsy tube abrasion. 5. Bending section bited, transformation. 6. Angle not enough, wires and helix tube abrasion. 7. Light guide tube aging and wrinkle. 8. Pins for wire holder leakage. Solution: Replace CCD, light bundle,insert tube, biopsy tube, bending section,helix tube, wires, light guide tube, pins

Ποιότητα Γαστροσκόπιο GIF-XQ240 της Olympus για επισκευή Εργοστάσιο

Γαστροσκόπιο GIF-XQ240 της Olympus για επισκευή

GIF-XQ240 Gastroscope by Olympus for repair ► Brief Description Fault: Leakage. Solution: Replace light guide tube,NO.1 button,wire,mesh,adjust angle. ►Problem & Solutoin Brand Olympus Model GIF-XQ240 Fault Leakage. Solution Replace light guide tube,NO.1 button,wire,mesh,adjust angle. ► Common issues with GIF-XQ240 Gastroscope No Image / Dark Image Poor Image Resolution / Blurry Image Ineffective Suction Difficulty with Angulation (Stiff or Loose) Bubbles in the Field of View

Ποιότητα T-R0037 Επισκευή ενδοσκόπου για Wolf Storz για τον τερματομηχανή τρυπανισμού Wolf Storz Εργοστάσιο

T-R0037 Επισκευή ενδοσκόπου για Wolf Storz για τον τερματομηχανή τρυπανισμού Wolf Storz

Product Description 1. Introduction T-R0037 Repair tool for Storz Wolf Olympus Stryker Rigid Endoscope Drilling Lathe Brand-new Perfectly repair rigid endoscope without scratch 2. Characteristics and Advantages Number:T-R0037 Features: Durable, Portable, Multi-functional Advantages: High Quality Materials, Precise Design, Easy To Use Main Material: Iron Weight: 20KG 3.Functions: Drilling hole 4.Quality and Reliability High-quality iron raw materials CNC machined Cutting,

Ποιότητα Τ-R0035 Ειδικός επισκευής ενδοσκόπησης για το Olympus Stryker Bench Vice Εργοστάσιο

Τ-R0035 Ειδικός επισκευής ενδοσκόπησης για το Olympus Stryker Bench Vice

Product Description 1. Introduction T-R0035 Repair tool for Storz Wolf Olympus Stryker Rigid Endoscope Bench Vice Brand-new Perfectly repair rigid endoscope without scratch 2. Characteristics and Advantages Number:T-R0035 Features: Durable, Portable, Multi-functional Advantages: High Quality Materials, Precise Design, Easy To Use Main Material: Iron Weight: 10KG 3.Functions: Disassembly and assembly 4.Quality and Reliability High-quality iron raw materials CNC machined