medical test tool
"
Τ-R0031 Φορητά εξαρτήματα επισκευής ενδοσκόπησης για το Storz Wolf Olympus Stryker 10x μεγεθυντικό γυαλί
Product Description 1. Introduction T-R0031 Repair tool for Storz Wolf Olympus Stryker Rigid Endoscope 10x Magnifying Glass Brand-new Perfectly repair rigid endoscope without scratch 2. Characteristics and Advantages Number:T-R0031 Features: Durable, Portable, Multi-functional Advantages: High ...
Τ-R0049 Εργαλείο επισκευής ενδοσκοπίου για τον Στόρζ Γουλφ Olympus Stryker
Product Description 1.Introduction T-R0049 Repair tool for Storz Wolf Olympus Stryker Rigid Endoscope Tube Light Bundle Brand-new Perfectly repair rigid endoscope without scratch 2. Characteristics and Advantages Number:T-R0049 Features: Durable, Portable, Multi-functional Advantages: High Quality ...
Εργαλεία επισκευής για τον Καρλ Στόρζ 495
Product Description 1. Introduction Repair Tool for KARL STORZ 495 TIP Light Guide Bundle Ring Brand-new Perfectly repair STORZ Fiber optic cable 2. Characteristics and Advantages Features: Durable, Portable, Multi-functional Advantages: High Quality Materials, Precise Design, Easy To Use Main ...
Ορετερορονοσκόπιο γερμανικής ποιότητας 4.5/6.5 6/7.5 6/8.5 8/9.8 8.5/11/5 Fr Για νοσοκομείο
German-quality Ureterorenoscope 4.5/6.5 6/7.5 6/8.5 8/9.8 8.5/11/5 Fr For Hospital ► Brief Description The function of a ureterorenoscope (URS) is primarily to allow a urologist to visualize, diagnose, and treat conditions in the upper urinary tract, which includes the ureter (the tube carrying ...
Karl Storz 27005BA Cystoscope for repair
Karl Storz 27005BA Cystoscope for repair ► Brief Description Fault: 1. No image. 2. Fiber abrasion. 3. Rod lens broken and cracked. 4. Objective lens broken and dirty. 5. Eyepiece cover broken. Solution: 1. Replace rod lens. 2. Replace inner tube. 3. Replace outer tube. 4. Replace objective lens ...
Το γαστροσκόπιο Olympus GIF-H170 για επισκευή
Olympus GIF-H170 gastroscope for repair ► Brief Description Fault: 1. The top left and middle right side with blur image, objective Lens broken. 2. 20% light bundle broken, the small lens turned yellow. 3. Insert tube yellow and wrinkles. 4. The biopsy tube abrasion. 5. The wire and helix tube ...
SonoScape EG-500 Ηλεκτρονική γαστροσκόπηση για επισκευή
SonoScape EG-500 Electronic Gastroscopy For Repair ► Brief Description Inspection Results: 1. No image display, CMOS water ingress fault; 2. 20% of the light bundle is broken; 3. There are bite marks on the insertion tube in multiple places; 4. The biopsy tube is worn out and not smooth; 5. The ...
Θορακόσκόπιο Olympus LTF-160 για επισκευή
Olympus LTF-160 thoracoscope for repair ► Brief Description Fault: 1.with image, but big risk for CCD after leakage. 2. Light bundle broken completely. 3. Insert tube with little scratch. 4. Biopsy tube abrasion and leakage. 5. Wires and helix tube abrasion. 6. Grip broken, leakage. 7. All the ...
Ενδοσκόπιο Olympus CHF-P20Q για επισκευή
Olympus CHF-P20Q endoscope for repair ► Brief Description Fault: 1.Insert tube cracked; 2.Rubber leakage; 3.Image with black point and cracked; 4.Angulation tight; 5.Biopsy tube aging Solution: Replace image bundle; insert tube; biopsy tube; bending mesh and wires; coil pipe; rubber ►Problem & ...